{"id":16183,"date":"2020-09-11T22:46:21","date_gmt":"2020-09-11T20:46:21","guid":{"rendered":"https:\/\/www.glucotab.at\/?p=16183"},"modified":"2022-11-24T16:00:35","modified_gmt":"2022-11-24T14:00:35","slug":"safe-and-sufficient-glycemic-control-by-using-a-digital-clinical-decision-support-system-for-patients-with-type-2-diabetes-in-a-routine-setting-on-general-hospital-wards","status":"publish","type":"post","link":"https:\/\/www.glucotab.at\/de\/safe-and-sufficient-glycemic-control-by-using-a-digital-clinical-decision-support-system-for-patients-with-type-2-diabetes-in-a-routine-setting-on-general-hospital-wards\/","title":{"rendered":"Safe and Sufficient Glycemic Control by Using a Digital Clinical Decision Support System for Patients With Type 2 Diabetes in a Routine Setting on General Hospital Wards"},"content":{"rendered":"<p>Sichere und ad\u00e4quate Kontrolle des Blutzuckerspiegels durch den Einsatz eines digitalen klinischen Entscheidungsunterst\u00fctzungssystems f\u00fcr Patienten mit Typ-2-Diabetes in einer Routineumgebung auf allgemeinen Krankenhausstationen<\/p>\n<p><em>J Diabetes Sci Technol<\/em>. September 2020:1932296820955243.<\/p>\n<p><a href=\"https:\/\/dx.doi.org\/10.1177\/1932296820955243\" target=\"_blank\" rel=\"noopener\">https:\/\/dx.doi.org\/10.1177\/1932296820955243<\/a><\/p>\n<p><a href=\"https:\/\/www.glucotab.at\/wp-content\/uploads\/2021\/03\/PMID32914640_Safe-and-Sufficient-Glycemic-Control-for-T2D-Patients-in-Routine-Setting-on-General-Hospital-Wards-3.pdf\" target=\"_blank\" rel=\"noopener\">Volltext herunterladen<\/a> (vom Verlag akzeptierte Version ohne Schriftsatz)<\/p>\n<p><!--more--><\/p>\n<p>Es sollte die Anwendbarkeit eines klinischen Entscheidungsunterst\u00fctzungssystems in einem realen station\u00e4ren Umfeld f\u00fcr Patienten mit Typ-2-Diabetes auf allgemeinen Krankenhausstationen untersucht werden. 150 Patienten mit Typ-2-Diabetes, die eine subkutane Insulintherapie ben\u00f6tigten, wurden mit einer Basis-Bolus Insulintherapie behandelt, die von einem Entscheidungsunterst\u00fctzungssystem (GlucoTab) gesteuert wurde, das automatisiert offene Aufgaben im Arbeitsprozess sowie Vorschl\u00e4ge f\u00fcr die Insulindosierung f\u00fcr das medizinische Fachpersonal bereitstellte. Unter Verwendung des Systems wurde ein mittlerer t\u00e4glicher Blutzucker (BZ) von 159 \u00b1 32 mg\/dL erreicht. 68,8% der Messungen lagen im Zielbereich (70 bis &lt;180 mg\/dL). Der Prozentsatz der BZ-Werte &lt;40, &lt;70 und \u2265300 mg\/dL betrug 0,02%, 2,2% bzw. 2,3%. Das Entscheidungsunterst\u00fctzungssystem erleichtert eine sichere und effektive station\u00e4re Diabetesbehandlung, indem es den Behandlungsablauf standardisiert und eine Entscheidungshilfe f\u00fcr die Basis-Bolus-Insulindosierung bietet.<\/p>\n<p><strong>Autoren<\/strong><\/p>\n<p>Katharina M Lichtenegger (1), Felix Aberer (1), Alexandru C Tuca (2), Klaus Donsa (3), Bernhard H\u00f6ll (3, 4), Lukas Schaupp (1), Johannes Plank (5), Peter Beck (3, 4), Friedrich M Fruhwald (6), Lars-Peter Kamolz (2), Thomas R Pieber (1, 3), Julia K Mader (1)<\/p>\n<p><strong>Autor Informationen<\/strong><\/p>\n<ol>\n<li>Department of Internal Medicine, Division of Endocrinology and Diabetology, Medical University of Graz, Austria.<\/li>\n<li>Department of Surgery, Division of Plastic, Aesthetic and Reconstructive Surgery, Medical University of Graz, Austria.<\/li>\n<li>Joanneum Research GmbH, HEALTH, Institute for Biomedicine and Health Sciences, Austria.<\/li>\n<li>decide Clinical Software GmbH, Austria.<\/li>\n<li>Department of Internal Medicine, Division of Gastroenterology and Hepatology, Medical University of Graz, Austria.<\/li>\n<li>Department of Internal Medicine, Division of Cardiology, Medical University of Graz, Austria.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Sichere und ad\u00e4quate Kontrolle des Blutzuckerspiegels durch den Einsatz eines digitalen klinischen Entscheidungsunterst\u00fctzungssystems f\u00fcr Patienten mit Typ-2-Diabetes in einer Routineumgebung auf allgemeinen Krankenhausstationen J Diabetes Sci Technol. September 2020:1932296820955243. https:\/\/dx.doi.org\/10.1177\/1932296820955243 Volltext herunterladen (vom Verlag akzeptierte Version ohne Schriftsatz)<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"cybocfi_hide_featured_image":"","footnotes":""},"categories":[9],"tags":[],"class_list":["post-16183","post","type-post","status-publish","format-standard","hentry","category-publikationen"],"_links":{"self":[{"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/posts\/16183","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/comments?post=16183"}],"version-history":[{"count":4,"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/posts\/16183\/revisions"}],"predecessor-version":[{"id":17998,"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/posts\/16183\/revisions\/17998"}],"wp:attachment":[{"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/media?parent=16183"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/categories?post=16183"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.glucotab.at\/de\/wp-json\/wp\/v2\/tags?post=16183"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}